Technical features:
1. Additional set of bubble alarm design(double bubble alarm) ensure more secure infusion;
2. Advanced safety design able to stop infusion and alarm even if the CPU damage,the medical staff can ues it safely;
3. Multipurpose: It can be transfused, transfused blood and transported nutrient solution;
4. Pumping way: Semi-squeeze finger-type peristaltic pump;
5. IV-sets: Special or quality PVC/TPE infusion sets with an external diameter of 3.4mm~4.5mm.
6. User options: no
7. Infusion modes: 4 infusion modes:
1)Flow-rate: ml/h;
2)Time-amount: ml/h;
3)Drop-rate: d/min;
4)Body-weight: mg/kg/h
8. Precision: Better than ±5% (using a calibrated or a special IV-set)
9. Safety classification: Class I; Internal power supply, CF type, IPX4 equipment
10. Optional accessories: 1)Warmer;
2)Wireless communicating module.
Technical parameters:
1. Flow-rate: 1.0~1200.0 ml/h, 0.1ml/h step
2. Time: 1s~99h59m59s, 1s step;
3. Drop-rate: 1~333 d/min, 1 d/min step;
4. Dose: 0.1~999.9 mg, 0.1mg step;
5. mg/kg/h: 0.001~999.999 mg/kg/h, 0.001 mg/kg/h step;
6. Body-weight: 1~300 kg, 1kg step;
7. KVO rate: 1.0~5.0 ml/h, 0.1 ml/h step;
8. Bolus rate: 50.0~800.0 ml/h, 0.1 ml/h step;
9. Bolus volume: 0.1~99.9 ml/h, 0.1ml step
10. Alarm: 1)Air in tube, 5 grades of sensitivity (double bubble alarm);
2)Bubble sensor fault;
3.1)Upper-end occlusion, -20~ -60 kPa,8 grades of sensitivity;
3.2)Upper-end base-pressure fault;
4.1)Lower-end occlusion, 20~ 140 kPa,8 grades of sensitivity;
4.2)Lower-end base-pressure fault;
5.1)Pump rotation fault;
5.2)Inverse-infusion;
6) Abnormal door-opening;
7) Low battery power, battery fault;
8) Overtime pause;
9) Completed infusion;
10) AC power fault;
11) MCU fault, and stop infusion;
12) Battery temperature is too high.
11. Data function: 1)Memory of calibration: Records the calibration data of tube automatically for application;
2)Memory of parameter: Records the latest infusion parameter for next operation;
3)Historical records: records latest 1000 infusion events.
(what/when/why,flow-rate, etc.)