Freezer Air Cooled Water Screw Absorption Chiller
- Payment Type:
- T/T
- Incoterm:
- FOB, CIF
- Min. Order:
- 1 Set/Sets
- Min. Order:
- 1 Set/Sets
- Delivery Time:
- 60 Days
- Transportation:
- Ocean, Land
Your message must be between 20 to 2000 characters
Contact NowPayment Type: | T/T |
---|---|
Incoterm: | FOB,CIF |
Transportation: | Ocean,Land |
Description and feature of HVAC Screw Water Chiller:
CWS-WSCS series industrial Aquarium Water Chiller are widely used in many industries like medium and large Scale industrial
cooling,central conditioning system,cold room,thermostatic chamber
Unit adopts Germany BITZER and Taiwan HANBELL brand semi-hermeitic High Pressure Air Compressor,The latest 5 or 6 patented Screw Air Compressor rotor profile with excellent efficiency.
Adjustable infinite or closely stepped capacity control, features energy efficient,stable and quiet running
Most advanced patented highest precision manufacturing process.
Built-in full intelligent monitoring and protection including thermal motor temperature monitoring,phase sequence monitoring,manual reset lock-out,oil temperature sensor.
Wide range of refrigerant for option,including R22 and R134a,R407c.
Microprogramming Servo Control System:industrial PLC centralized control combined with Industrial Air Compressor capacity control system,precisely monitor.
Integrated protection for low temperature,high/low pressure,anti-freezing,phase missing, anti-phase,overland,motor over temperature,oil differential,flow switch,start up latency.
Optional operation language,menu leading,unit running state easy to adjust.
Easy installation,running:Closely stepped start-up,minimize impact to electricity.
Steady and safe running,low vibration.
Compact structure,less space demand and light in weight,easy for transport and installation.
Completely wired, inspected and tested pre-delivery,saving installation time and cost.
Note: 1.Rated cooling capacity is based on: the chilled water inlet and outlet temperature 12℃/ 7℃; cooling air inlet and outlet temperature 30℃/35℃.
2.Scope of work: chilled water temperature range: 5℃ to 30℃; chilled water inlet and
outlet temperature difference: 3℃ to 8℃.
Best cooling temperature range: 15-30℃; recommend to use in ambient temperatures below 38℃; cooling air inlet and outlet temperature difference: 8℃ to 10℃.
The above chillers can be customized according to customers' requirements.
Specifications and dimensions above are subject to change without notice.
Advantages of Water-cooled screw chiller:
Water-cooled screw chillers are applied to wide fields: Such as plastic, electroplating, electronics, chemical, medical, cleaning, food, metallurgical and other industries, which can cool off their facilities. It also provide high-performance water systems for shopping malls, office buildings, hotels, hospitals, residential villas and other places, which create a quiet and comfortable living and working environment our customers.
1. Features :
High-efficient semi-enclosed double-compressor screw chiller: the unit running smoothly; low noise ;
Inhaling air cools down running temperature of the motor, which can ensure long life of motor;
Using high-quality bearing; Bearing life: at least 40,000 hours;
Built-in oil separator, small seize, better effect ;
Realizing stepwise or infinitive range of energy regulation from 0 % to 100%,it can save power resources maximally;
Condenser adopts high-performance shell and tube heat exchanger (also can select stainless steel plate heat exchanger), which has built-in high-efficient teeth-tube heat
exchanger. Rational design and good heat transfer effect ;
Evaporator adopts high-performance shell and tube heat exchanger (also can select stainless steel plate heat exchanger), which has built-in high-efficient teeth-tube heat
exchanger. Rational design and good heat transfer effect;
Suiting for R22, R407c, R 134a, R404A refrigerants ect ;
Less moving parts and low mal-function rate;
Optionally equip with economizer to further improve the compressor' s cooling capacity and efficiency;
Optionally equip with liquid spray cooling devices to extend the application range of the compressor ;
Optionally equip with an engine oil device to increase the efficiency of the compressor and the application range of compressor.
2. Easy to use, more control functions:
Realizing starting-on control process, energy regulating process, stop control process, mal-function auto-stop, mal-function diagnosis, statistics of operation time, operating
status display and reboot recovery process ;
Intact control functions and protection functions, simple Chinese-English interface
Computer LCD touch screen controller, which can reflect the running situation well. The operation is more convenient;
Optionally connect the Bo Lou Yu control system (need to order a control module additionally) or remote control system ;
With chilled water pump, cooling water pump, cooling tower chain control function;
Host is highly automated; do without special person to manage.
Notes:1.Rated cooling capacity is based on: the chilled water inlet and outlet temperature 12℃/
7℃; cooling air inlet and outlet temperature 30℃/35℃.
2.Chilled water temperature range: 5℃ to 30℃; chilled water inlet and out let temperature difference: 3℃ to 8℃; cooling water temperature range: 18℃ to 30℃;
Cooling water temperature range: 18℃ to 30℃; cooling water inlet and outlet temperature difference: 3.5℃ to 10℃.
The above chillers can be customized according to customers' requirements.
Specifications and dimensions above are subject to change without notice.
The less common open loop industrial chillers control the temperature of a liquid in an open tank or sump by constantly recirculating it. The liquid is drawn from the tank, pumped through the chiller and back to the tank. In industrial water chillers is the use of water cooling instead of air cooling. In this case the condenser does not cool the hot refrigerant with ambient air, but uses water that is cooled by a cooling tower. This development allows a reduction in energy requirements by more than 15% and also allows a significant reduction in the size of the chiller, due to the small surface area of the water-based condenser and the absence of fans. Additionally, the absence of fans allows for significantly reduced noise levels.