Introduction:
Irradiation cross-linkable flame-retardant polyolefin low-Smoke non-halogen compound is based on polyolefin resin, which is mixed with non-halogen flame retardant, cross-linkable agent, and other process agent, to knead, plastify, and then extrude into pellets. It has excellent mechanical property, oil resistance, electirc property, flame-retardant property and processing properties. Moreover, it features the advantage of no halogen and low smoke amount giving out, which can be used in power cable, control cable, marine cable, optical cable and signal cable etc.

MG80017-90(J/H) 90°C irradiation cross-likable Flame-retardant polyolefin low-Smoke non-halogen insulating(sheating) compound MG80017-105(J/H) 105°Cirradiation cross-linkable Flame-retardant polyolefin low-Smoke non-halogen insulating(sheating) compound MG80017-125(J/H) 125°C irradiation cross-linkable Flame-retardant polyolefin low-Smoke non-halogen insulating(sheating) compound

Test Items Unit Typical Value
MG80017-90(J/H) MG80017-105(J/H) MG80017-125(J/H)
Density(23°C) g/cm3 1.45 1.44 1.45
Tensile strength MPa 12.3 12.7 13.1
Elongation at break % 220 210 200
Hot setting test 200°C x 15min,0.2MPa
Elongation under lood % 65 70 80
Permanent elongation after cooling °Cxh 121x168 136x168 158x168
Retaintion of Tensile strength % 109 112 110
Retaintion of Elongation at break % 89 87 85
low temperature impact Brittleness °C -25 pass -25 pass -25 pass
20°C Volume resistivity Ω.cm 5.6x1014 3.7x1014 4.5x1014
Dielectirc strength MV/m 26 28 27
Oxygen index % 34 35 33
Acid gas emission mg/g 0 0 0
pH   5.9 6.0 5.8
Conductivity μs/mm 0.8 0.7 0.5
Dm(1.0mm) Smoke density flame 56 61 54
non-flame 152 159 162

Irradiation dosage:
Irradiation dosage is different from the cable and da, genlerally 10-15MRAD recommended. ♦ Variety Colours ♦ Workshop show ♦ Company Certifications: ◊ ISO 9001:2008 ◊ ISO 14001:2004 ◊ Certification of UL  