Suzhou yacoo chemical reagent corporation company
Suzhou yacoo chemical reagent corporation company
NEM Trinder Reagent N-Ethylmaleimide CAS  NO128-53-0 98% Ma
  • NEM Trinder Reagent N-Ethylmaleimide CAS  NO128-53-0 98% Ma
NEM Trinder Reagent N-Ethylmaleimide CAS  NO128-53-0 98% Ma

NEM Trinder Reagent N-Ethylmaleimide CAS NO128-53-0 98% Ma

Min. Order:
1
Min. Order:
1
Delivery Time:
30 Days
Quantity:

Your message must be between 20 to 2000 characters

Contact Now
Basic Info
Basic Info
Place of Origin: China
Product Description
Product Description

NEM Trinder Reagent N-Ethylmaleimide CAS NO128-53-0 98%

Quick Detail:

Name

NEM

Appearance

White to light yellow crystalline powder

Assay:

98%

Solubility(50 mg/ml Ethanol)

Clear

MP/℃

41-45

BP/℃

210 °C

Ammonium Sulfate,%

Free fatty acids, mg/g

Description:

> CAS NO: 128-53-0

> Formula:C6H7NO2

> weight:125.13

> Appearance: White to light yellow crystalline powder

> Storage: 2-8℃,in dark place

> safety description:S26

> danger description:R21 R28 R34

> danger symbol:T+

Specifications

Assay

98%

Solubility(50 mg/ml Ethanol)

Clear

MP/℃

41-45

BP/℃

210

Ammonium Sulfate,%

BSA purity,%

Free fatty acids, mg/g

Shelf life

One year

Synonyms:

1-ethyl-1h-pyrrole-5-dione;5-dione,1-ethyl-1H-Pyrrole-2;ethvlmaleimide;Ethylmaleimide;Maleic acid N-ethylimide;maleicacidn-ethylimide;Maleimide, N-ethyl-;n-ethvlmaleimide;NEM; N-Ethylmaleimide, (NEM); 1-Ethyl-1H-pyrrole-2,5-dione~NEM; 1-ethyl-1H-pyrrole-2,5-dione

Related categories:

N-Substituted Maleimides;N-Substituted Maleimides, Succinimides &Phthalimides;Amines;Heterocycles;Life Science Chemical Reagents

Related Products:

Determination of melting point

Instrument:

Micro melting point apparatus WRS-2A, Melting point tubes

Determination of step:

Open switch, stable 20min.

First set the starting temperature than the melting point of the low 10 ℃, heating rate 2 ℃ / min.

The sample was grind as fine as possible and load in a clean, dry melting point pipe ,until the sample was compressed into about 1cm high .When the actual temperature reaches the set temperature and stabilized . Inserted into the capillary with the sample, the simultaneous determination of three.

The determination of solubility

Weigh a certain amount of samples into test tube, add a certain amount of water, shake and dissolve, observe the solution.

Send your message to this supplier

  • Ms. Miss. Adela

  • Enter between 20 to 4,000 characters.

Related Keywords

Related Keywords