Suzhou Union Tech Import & Export Co. Ltd
Suzhou Union Tech Import & Export Co. Ltd
Ventilator with alarming functions, compatible with air compressor
  • Ventilator with alarming functions, compatible with air compressor
Ventilator with alarming functions, compatible with air compressor

Ventilator with alarming functions, compatible with air compressor

Payment Type:
T/T, L/C or Western Union
Quantity:

Your message must be between 20 to 2000 characters

Contact Now
Basic Info
Basic Info
Payment Type: T/T, L/C or Western Union
Product Description
Product Description
  • Main features:
    • Two driven mode: electric and pneumatical
    • Applicable to both adults and children
    • TFT LCD display screen
    • Multiple working mode and ventilation modes such as IPPV, A/C,PCV, SIMV, SPONT/CPAP, PSV, SIGH and MAUN
    • With alarming functions
    • With realtime compensation function
    • With air and oxygen mixer of high accuracy, stable andreliable
    • With built-in spare power source, when outside power sourcegoes off, spare power source starts to work
    • Compatible with air compressor
  • Working condition:
    • Gas source: O2
    • Air compressor
    • Rated working pressure: 280 to 600kpa
    • Power source:
      • Voltage: 220 ±22V
      • Frequency: 50 ±1Hz
    • Main parameters:
      • Adjusting range of parameters:
        • Frequency: 1 to 100bpm
        • SIMV mode: 1 to 40bpm
        • Other modes:
          • Adult: 4 to 40bpm
          • Children: 20 to 100bpm
      • Tinsp (Inspiratory time): 0 to 12s (except for SIMV moderespiratory ratio: 4:1 to 1:8)
      • VT (Tidal volume) range: 0 to 2000mL
      • Adult: 25 to 2000mL
      • Children: 0 to 300mL
      • PEEP: 0 to 40cmH2O
      • CPAP: 0 to 20cmH2O
      • Continuous air flow:
        • Adult: 0 to 60L/min
        • Children: 2 to 30L/min
      • PTr (Pressure trigger): -20 to 20cmH2O
      • FTr (Flow trigger): 0.5 to 30L/min
      • Pc (Pressure control): 5 to 80cmH2O
      • Ps (Pressure supports): 0 to 80cmH2O
      • Adjusting range of O2 concentration: 21 to 100%
      • Holding time (inhalation platform/TIP): 0 to 6s (≤50%inspiratory time)
      • SIGH adjusting range: 1/100 to 5/100
      • Suffocation ventilation: Off, 5 to 60s
      • Pressure limit range: 20 to 100cmH2O
      • Maximum safety pressure: <12.5Kpa
    • Monitoring parameters:
      • Frequency: 0 to 100/min
      • VT (Tidal volume): 0 to 2500mL
      • MV (Tidal volume/min): 0 to 99L/min
      • Tube pressure: 0 to 100cmH2O
      • Concentration of inhaled oxygen: 15 to 100 %
  • Two driven mode: electric and pneumatical
  • Applicable to both adults and children
  • TFT LCD display screen
  • Multiple working mode and ventilation modes such as IPPV, A/C,PCV, SIMV, SPONT/CPAP, PSV, SIGH and MAUN
  • With alarming functions
  • With realtime compensation function
  • With air and oxygen mixer of high accuracy, stable andreliable
  • With built-in spare power source, when outside power sourcegoes off, spare power source starts to work
  • Compatible with air compressor
  • Gas source: O2
  • Air compressor
  • Rated working pressure: 280 to 600kpa
  • Power source:
    • Voltage: 220 ±22V
    • Frequency: 50 ±1Hz
  • Main parameters:
    • Adjusting range of parameters:
      • Frequency: 1 to 100bpm
      • SIMV mode: 1 to 40bpm
      • Other modes:
        • Adult: 4 to 40bpm
        • Children: 20 to 100bpm
    • Tinsp (Inspiratory time): 0 to 12s (except for SIMV moderespiratory ratio: 4:1 to 1:8)
    • VT (Tidal volume) range: 0 to 2000mL
    • Adult: 25 to 2000mL
    • Children: 0 to 300mL
    • PEEP: 0 to 40cmH2O
    • CPAP: 0 to 20cmH2O
    • Continuous air flow:
      • Adult: 0 to 60L/min
      • Children: 2 to 30L/min
    • PTr (Pressure trigger): -20 to 20cmH2O
    • FTr (Flow trigger): 0.5 to 30L/min
    • Pc (Pressure control): 5 to 80cmH2O
    • Ps (Pressure supports): 0 to 80cmH2O
    • Adjusting range of O2 concentration: 21 to 100%
    • Holding time (inhalation platform/TIP): 0 to 6s (≤50%inspiratory time)
    • SIGH adjusting range: 1/100 to 5/100
    • Suffocation ventilation: Off, 5 to 60s
    • Pressure limit range: 20 to 100cmH2O
    • Maximum safety pressure: <12.5Kpa
  • Monitoring parameters:
    • Frequency: 0 to 100/min
    • VT (Tidal volume): 0 to 2500mL
    • MV (Tidal volume/min): 0 to 99L/min
    • Tube pressure: 0 to 100cmH2O
    • Concentration of inhaled oxygen: 15 to 100 %
  • Voltage: 220 ±22V
  • Frequency: 50 ±1Hz
  • Adjusting range of parameters:
    • Frequency: 1 to 100bpm
    • SIMV mode: 1 to 40bpm
    • Other modes:
      • Adult: 4 to 40bpm
      • Children: 20 to 100bpm
  • Tinsp (Inspiratory time): 0 to 12s (except for SIMV moderespiratory ratio: 4:1 to 1:8)
  • VT (Tidal volume) range: 0 to 2000mL
  • Adult: 25 to 2000mL
  • Children: 0 to 300mL
  • PEEP: 0 to 40cmH2O
  • CPAP: 0 to 20cmH2O
  • Continuous air flow:
    • Adult: 0 to 60L/min
    • Children: 2 to 30L/min
  • PTr (Pressure trigger): -20 to 20cmH2O
  • FTr (Flow trigger): 0.5 to 30L/min
  • Pc (Pressure control): 5 to 80cmH2O
  • Ps (Pressure supports): 0 to 80cmH2O
  • Adjusting range of O2 concentration: 21 to 100%
  • Holding time (inhalation platform/TIP): 0 to 6s (≤50%inspiratory time)
  • SIGH adjusting range: 1/100 to 5/100
  • Suffocation ventilation: Off, 5 to 60s
  • Pressure limit range: 20 to 100cmH2O
  • Maximum safety pressure: <12.5Kpa
  • Frequency: 1 to 100bpm
  • SIMV mode: 1 to 40bpm
  • Other modes:
    • Adult: 4 to 40bpm
    • Children: 20 to 100bpm
  • Adult: 4 to 40bpm
  • Children: 20 to 100bpm
  • Adult: 0 to 60L/min
  • Children: 2 to 30L/min
  • Frequency: 0 to 100/min
  • VT (Tidal volume): 0 to 2500mL
  • MV (Tidal volume/min): 0 to 99L/min
  • Tube pressure: 0 to 100cmH2O
  • Concentration of inhaled oxygen: 15 to 100 %
  • Send your message to this supplier

    • Mr.  Steven

    • Enter between 20 to 4,000 characters.

    Related Keywords