CPAP System Ventilator, Environment-friendly, Continuous Operating
  • CPAP System Ventilator, Environment-friendly, Continuous Operating
CPAP System Ventilator, Environment-friendly, Continuous Operating

CPAP System Ventilator, Environment-friendly, Continuous Operating

Payment Type:
T/T, L/C or Western Union
Quantity:

Your message must be between 20 to 2000 characters

Contact Now
Basic Info
Basic Info
Payment Type: T/T, L/C or Western Union
Product Description
Product Description
  • Main technical specification:
  • Environment-friendly
  • Working environment:
    • Ambient temperature: 5 to 40°C
    • Relative humidity: ≤80 %
    • Atmospheric pressure: 960 to 1040hPa
  • Storage and transportation environment:
    • Ambient temperature: -10 to +40°C
    • Relative humidity: ≤90 %
    • Atmospheric pressure: 860 to 1060hPa
  • Ambient temperature: 5 to 40°C
  • Relative humidity: ≤80 %
  • Atmospheric pressure: 960 to 1040hPa
  • Ambient temperature: -10 to +40°C
  • Relative humidity: ≤90 %
  • Atmospheric pressure: 860 to 1060hPa
  • Classification:
  • According to IEC 60601-1, this machine belongs to:
  • Class I, internally powered equipment
  • Type B applied part
  • Normal equipment
  • Continuous operating
  • Sterilization (refer to chapter 9 of clearance andsterilization)
  • Gas supply:
  • Gas source O2 (for medical use)
  • Air (for medical use)
  • Rated working pressure: 350kPa
  • Output pressure of regulator: 350 ±50kPa (300 to400kPa)
  • Power supply:
  • Voltage: 220 to ±22V
  • Frequency: 50 ±1Hz
  • Input power: 900VA
  • Main unit: 25W
  • Air compressor: 675W
  • Internal power: 12V DC, 4Ah
  • Fuse:
    • AC power for main unit: 5T T1AL 250V
    • Battery: 5T T2AL 250V
    • AC power for air compressor: 5T T6.3AL 250V
    • AC power for machine: 5T T10AL 250V
  • AC power for main unit: 5T T1AL 250V
  • Battery: 5T T2AL 250V
  • AC power for air compressor: 5T T6.3AL 250V
  • AC power for machine: 5T T10AL 250V
  • Electromagnetic compatibility:
  • Cell phone and other radiation equipment used near the machinewill cause unexpected problem to ventilator
  • Other equipment added to ventilator will lead to disturbance tomachine
  • Before used to the patient, check if the machine works normallyunder the set values
  • Parameter adjustment:
  • FiO2
  • Adjusting range: 21 to 100 %
  • Accuracy: ±15 %
  • CPAP adjusting range: 0 to 15cm H2O
  • Continuous flow adjusting range: 2 to 20L/min
  • Continuous flow adjusting range for manual: 20 to±5L/min