Medical Anesthesia Trolley (THR-MJ-560B1)
- Payment Type:
- L/C, T/T, Western Union
Quantity:
Your message must be between 20 to 2000 characters
Contact NowBasic Info
Basic Info
Place of Origin: | Jiangsu, China (Mainland) |
---|---|
Payment Type: | L/C, T/T, Western Union |
Product Description
Product Description
THR-MJ-560B1 Medical Anesthesia Trolley
Medical Anesthesia Trolley
-various evaporator
-Double-tube O2 flowmeter
-standard loop system
-screen display ventilator
Standard Configuration:
One High-precision evaporator, either Halothane, Enflurane, Isoflurane or Sevoflurane configuration.
Double-tubes O2 flowmeter, standard loop system, ABS Engineered plastic frame, children or adult bellows, screen display ventilator (IPPV, MANUAL, ventilation volume, tidal volume, respiratory rate), real-time display of respiratory duct pressure, clear at one glance)
Optional: CO2 concentration monitoring
THR-MJ-560B1 is an economic type of anesthesia machine.
1) The high-precision Vaporizer is designed with a stable concentration output, automatic compensation for pressure, temperature and flow rate. And it is available to choose one kind of gas from Halothane, Enflurane, Isoflurane, and Sevoflurane, ensuring a successful anesthesia operation.
2) Reliable pneumatic transmission system.
3) Economic and proper configuration of technologies, optional as required by the Customer.
4) Modularized design and upgrading. Upgrading is available as required by the Customer.
Part of Ventilator:
Display mode High-definition 4.8" LCD screen display
Ventilation mode IPPV, MANUAL (Manual monitoring of tidal volume, ventilation volume, respiratory rate)
Ventilation parametersTidal volume 50~1500ml
Rate 4~80 bpm
I: E 2: 1~1: 4
Pressure range 1.0~6.0 kPa
Parameters for ventilation monito ringtidal volume, ventilation volume, IPPV rate, I/E, peak pressure of airway, inspiratory trigger pressure, pressure - time waveform.
Security Alarm System
Airway pressure alarm upper limit setting range 1.0~6.0 kPa
Low limit setting range0.4~2.0 kPa
TV alarm upper limit setting range 0.5~2.0L
Low limit setting range 0.02~1.0L
Sustained high-pressure alarm it will give alarm when stress have consistently
Been higher than 2.5 kPa
Suffocation alarm it will give sound and light alarm if there is
No tidal volume input in 15s
Power alarm
Power AC 110-220V± 10% 50-60Hz± 1Hz
Medical Anesthesia Trolley
-various evaporator
-Double-tube O2 flowmeter
-standard loop system
-screen display ventilator
Standard Configuration:
One High-precision evaporator, either Halothane, Enflurane, Isoflurane or Sevoflurane configuration.
Double-tubes O2 flowmeter, standard loop system, ABS Engineered plastic frame, children or adult bellows, screen display ventilator (IPPV, MANUAL, ventilation volume, tidal volume, respiratory rate), real-time display of respiratory duct pressure, clear at one glance)
Optional: CO2 concentration monitoring
THR-MJ-560B1 is an economic type of anesthesia machine.
1) The high-precision Vaporizer is designed with a stable concentration output, automatic compensation for pressure, temperature and flow rate. And it is available to choose one kind of gas from Halothane, Enflurane, Isoflurane, and Sevoflurane, ensuring a successful anesthesia operation.
2) Reliable pneumatic transmission system.
3) Economic and proper configuration of technologies, optional as required by the Customer.
4) Modularized design and upgrading. Upgrading is available as required by the Customer.
Part of Ventilator:
Display mode High-definition 4.8" LCD screen display
Ventilation mode IPPV, MANUAL (Manual monitoring of tidal volume, ventilation volume, respiratory rate)
Ventilation parametersTidal volume 50~1500ml
Rate 4~80 bpm
I: E 2: 1~1: 4
Pressure range 1.0~6.0 kPa
Parameters for ventilation monito ringtidal volume, ventilation volume, IPPV rate, I/E, peak pressure of airway, inspiratory trigger pressure, pressure - time waveform.
Security Alarm System
Airway pressure alarm upper limit setting range 1.0~6.0 kPa
Low limit setting range0.4~2.0 kPa
TV alarm upper limit setting range 0.5~2.0L
Low limit setting range 0.02~1.0L
Sustained high-pressure alarm it will give alarm when stress have consistently
Been higher than 2.5 kPa
Suffocation alarm it will give sound and light alarm if there is
No tidal volume input in 15s
Power alarm
Power AC 110-220V± 10% 50-60Hz± 1Hz